Main Content

SPICE-Imported MOSFET

Predefined MOSFET parameterized by external SPICE subcircuit

  • Library:
  • Simscape / Electrical / Semiconductors & Converters

Description

The SPICE-Imported MOSFET block models a metal-oxide-semiconductor field-effect transistor (MOSFET) that has been parameterized using an external SPICE subcircuit.

You can use this block to model the MOSFET devices listed in the table. These parameterizations have already been imported to Simscape using the subcircuit2ssc function, and they have been numerically validated against results generated using a SPICE simulation tool.

Available Parameterizations

SeriesDevice
Infineon OptiMOS6 40VIAUC120N04S6N009
IAUC120N04S6N010
IAUC120N04S6N013
IAUC100N04S6N015
IAUC100N04S6N022
IAUC100N04S6N028
IAUC80N04S6N036
IAUC60N04S6N036
IAUC120N04S6L008
IAUC120N04S6L009
IAUC120N04S6L012
IAUC100N04S6L014
IAUC100N04S6L020
IAUC100N04S6L025
IAUC80N04S6L032
IAUC60N04S6L039
Infineon OptiMOS5 80VIPB015N08N5
IPB017N08N5
IPP020N08N5
IPT012N08N5
IPB020N08N5
IPP023N08N5
IPB024N08N5
IPP027N08N5
IPB031N08N5
IPP034N08N5
IPB049N08N5
IPP052N08N5
IAUT300N08S5N012
IAUT165N08S5N029
IAUT300N08S5N014
IAUT240N08S5N019
IAUT200N08S5N023
IAUS300N08S5N013T
IAUS300N08S5N015T
IAUC100N08S5N031
IAUC100N08S5N043
IAUC70N08S5N074

Limitations

  • This block only works when the local solver is enabled. To enable the local solver, select the Use local solver check box in the Solver Configuration block. You must set the Sample time parameter to a value smaller than the fastest device dynamic. If you specify a larger sample time, the block steps over the dynamic events, which results in numerical warnings.

  • Copying this block from the library into a model breaks the link to the library. If you upgrade MATLAB to later versions, you need to replace this block with a new copy of the block from the library.

Ports

Conserving

expand all

Electrical conserving port associated with the gate terminal of the chosen pre-parameterized MOSFET.

Electrical conserving port associated with the drain terminal of the chosen pre-parameterized MOSFET.

Electrical conserving port associated with the junction temperature of the chosen pre-parameterized MOSFET.

Electrical conserving port associated with the case temperature of the chosen pre-parameterized MOSFET.

Electrical conserving port associated with the source of the chosen pre-parameterized MOSFET.

Parameters

expand all

Series of the pre-parameterized MOSFET, specified as either Infineon OptiMOS6 40V or Infineon OptiMOS5 80V.

Name of the device, specified as one of the options listed in the Available Parameterizations table.

Extended Capabilities

C/C++ Code Generation
Generate C and C++ code using Simulink® Coder™.

Introduced in R2020b