The Diagnostics > Stateflow category includes parameters for detecting issues related to Stateflow® charts.
Parameter | Description |
---|---|
Select the diagnostic action to take for detection of unused data, events, and messages in a chart. Removing unused data, events, and messages can minimize the size of your model. | |
Select the diagnostic action to take when a chart junction has both of the following conditions. The junction:
| |
Select the diagnostic action to take when a chart:
| |
Select the diagnostic action to take when a chart does not have an unconditional default transition to a state. | |
Select the diagnostic action to take when a chart contains a transition that loops outside of the parent state or junction. | |
Select the diagnostic action to take when a chart contains undirected local event broadcasts. | |
Select the diagnostic action to take when a transition action executes before a condition action in a transition path with multiple transition segments. | |
Select the diagnostic action to take when a Moore chart uses a previous output value to determine the current state. | |
Select the diagnostic action to take when a state or transition absolute time operator uses a time value that is shorter than the sample time for the Stateflow block. | |
Select the diagnostic action to take when you can remove a self-transition on a leaf state. | |
Execute-at-Initialization disabled in presence of input events | Select the diagnostic action to take when Stateflow detects triggered or enabled charts that are not running at initialization. |
Select the diagnostic action to take when there are chart constructs not on a valid execution path. |