db_0123: Stateflow port names
Since R2020a
Guideline Publication
Control Algorithm Modeling Guidelines - Using MATLAB®, Simulink®, and Stateflow
Sub ID Recommendations
NA-MAAB — a
JMAAB — Not supported
MATLAB Versions
All
Rule
Sub ID a
The name of a Stateflow input/output shall be the same as the corresponding signal.
Reusable Stateflow blocks can have different port names.
Not Applicable
Rationale
Sub ID a:
Improves readability.
Code generation may not be possible.
Verification
Model Advisor check: Check for names of Stateflow ports and associated signals (Simulink Check)
Last Changed
R2020a
See Also
Set Data Properties (Stateflow)
Reusable Components in Charts (Stateflow)
Version History
Introduced in R2020a