With the mechanical speed as input is it the asynchronous machine working as a generator?

Hi
I'm using the builtin block of the asynchronous machine insimulink which receives as input the mechanical speed from a custom block I've made which represents a turbine. As I read on the simulink documentation when we set the mechanical speed as input we force the block (asynchronous machine) to operate as a generator (which is what I want) but the speed of the asynchronous machine never gets above of the synchronous speed. Is it really working like a generator this way?

Categorías

Más información sobre Modeling en Centro de ayuda y File Exchange.

Preguntada:

el 21 de Mayo de 2014

Respondida:

el 22 de Mayo de 2014

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by