The simulink simulation slows down when I use a switch, it does not give any error but it stays at .5 second indifinitely!
Mostrar comentarios más antiguos
I am trying to select one output from two blocks depending on certain conditions, and then forward that signal as input to another block, but the simulation almost comes to a standstill and I also get no error. What could be the problem?
Respuestas (2)
You will need to use Simulation->Model Configuration Parameters->Solver to adjust your solver types, tolerances, and/or step sizes to account for the stiffness of the switch.
1 comentario
Yeow Yu Leong
el 7 de Jun. de 2024
Thanks dude, this is working
The solution of changing the solver parameters didn't work for me, but I found a workaround :
instead of using the manual switch block, I use the signal compare switch connected to a constant controlled by a push button.
I think the manual switch block is simply broken so I will avoid it in the future.

Categorías
Más información sobre Sources en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!