How to store and retrieve value in simulink
Mostrar comentarios más antiguos
Hi I'm Rofiq
I'm doing project in simulink which doing battery simulation with equation for example x(k+1)=x(k)+P(k) where x(k+1) is the energy stored in battery at time k+1 that is equal to energy stored in battery at time k plus/minus amount energy that charge/discharge to or from battery at time k
What block I should use to build above simulation, I need some block that can store my input value at time k (charging phenomena) and then use/retrieve it at another time k+10 (discharging phenomena). This block/variable act like battery which can inform how much energy stored at time instance and also increase/ decrease over sample time
Thank you for the help
Respuesta aceptada
Más respuestas (5)
lokesh kumar
el 13 de Sept. de 2021
1 voto
Tapped Delay block could help you on this. It stores all previous values of how much delay you set in the block...It will store it in a vector format and at last you can access it altogether at once.

ahmad rofiq
el 22 de Abr. de 2015
0 votos
ahmad rofiq
el 22 de Abr. de 2015
0 votos
Walter Roberson
el 4 de Mayo de 2015
0 votos
Your x is effectively an integrator applied to P so use an integrator block.
Purushottama Rao
el 4 de Mayo de 2015
0 votos
You can use integer delay block.