Does variation point blocks get generated for OPERATION-INVOKED-EVENT runnables ?

4 visualizaciones (últimos 30 días)
I have added Variation points for a runnable like below from systemdesk
<RUNNABLE-ENTITY UUID="32a97bd4-8cc3-443b-979d-8423bf9af7c1">
<SHORT-NAME>ActvAirDamCtrlDTIStart</SHORT-NAME>
<MINIMUM-START-INTERVAL>0</MINIMUM-START-INTERVAL>
<CAN-BE-INVOKED-CONCURRENTLY>true</CAN-BE-INVOKED-CONCURRENTLY>
<SYMBOL>ActvAirDamCtrl_ActvAirDamCtrlDTIStart</SYMBOL>
<VARIATION-POINT>
<SHORT-LABEL>ActvAirDamVPnt</SHORT-LABEL>
<SW-SYSCOND BINDING-TIME="PRE-COMPILE-TIME">
<SYSC-STRING-REF DEST="SW-SYSTEMCONST">/FCAVariants/VariantManagement/BuildActvAirDam</SYSC-STRING-REF>==1</SW-SYSCOND>
</VARIATION-POINT>
</RUNNABLE-ENTITY>
But once the model is created the runnable does not contain this variation point

Respuestas (1)

akshatsood
akshatsood el 13 de Ag. de 2024
Editada: akshatsood el 13 de Ag. de 2024
Dear @Vishnu
I understand that you have added variation points for a runnable element in SystemDesk and imported it into Simulink. However, the runnable does not contain this variation point.
As mentioned in the following documentation, "VARIANT-POINT" entries appear for AUTOSAR ports, runnables, and runnable accesses to external data:
Can you try replacing "SYSC-STRING-REF" with "SYSC-REF" as detailed in the above documentation and reimporting to see if this helps? I believe there might be compatibility issues between Simulink and SystemDesk.
Please refer to the attached documentation for detailed guidance on configuring variants for AUTOSAR elements.
I hope this helps.

Categorías