In which cases the coverage report (MCDC & Condition) of a block is influenced by the connection of the block's output with a scope?
Mostrar comentarios más antiguos
I have an AND block in a subsystem in Simulink and the coverage report shows that the input of the Port 2 was never false (for more details see fig1). The output of the AND block, the Input of Port 1 and the Input of Port 2 are shown respectively in fig 2. However, after connecting the Scope with the AND block (see fig1), the coverage result changed to 100% for this block.
I ran the simulation with fixed discrete step. The AND block is indeed in a subsystem but this subsystem is not triggered by any signal. What should I check to solve this issue?
Kind regards
3 comentarios
Birdman
el 29 de Mzo. de 2018
Can you share your model?
ada dil
el 29 de Mzo. de 2018
Amiit Pandey
el 22 de Mzo. de 2022
Did you get any positive response?
Respuestas (1)
Akshat Dalal
el 26 de Oct. de 2024
0 votos
Hi Ada,
This could be because Simulink typically optimizes simulation by omitting some test-cases. However, when a scope block is there, these cannot be optimized and thus you get complete coverage.
To get complete coverage without scope block by avoiding these optimizations, you can disable the 'Conditional input branch execution' setting. To do this, navigate to 'Configuration Parameters -> Simulation Target -> Advanced Parameters' tab and ensure that the parameter is turned off. Remember to disable this parameter for the configurations of all model references as well.