I am trying to simulate a phasor domain model of grid connected wind generator. In this i want to add a battery bank and this battery will be supply power to a critical three phase load. Hence i need a battery and inverter in phasor domain.
  1 comentario
Chulin Xu
Chulin Xu el 12 de Feb. de 2021
hi,did you find a solution? I am face the same problem now

Iniciar sesión para comentar.

Respuestas (1)

Sabin
Sabin el 11 de Feb. de 2023
The way phasor (or frequency and time in Simscape technology) are working is different to the time simulation. If, in a linear circuit, you are interested only in the changes in magnitude and phase of all voltages and currents when switches are closed or opened, you do not need to solve all differential equations (state-space model) resulting from the interaction of R, L, and C elements. You can instead solve a much simpler set of algebraic equations relating the voltage and current phasors. Phasors are complex numbers representing sinusoidal voltages and currents at a particular frequency. Therefore, it is not possible to use a switching device. Best to use an alternative implementation, at constant frequency, using supported blocks.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by