photo

Abhi Shankar Abhinav

MathWorks

Last seen: 3 días hace Con actividad desde 2020

Followers: 0   Following: 0

Estadística

  • Knowledgeable Level 1
  • First Review
  • Revival Level 1
  • First Answer

Ver insignias

Feeds

Ver por

Respondida
Not able to run open_system('mcb_pmsm_foc_sensorless_nucleo_f401re.slx');
Please reach out to support as this maybe specifc to your install and tools on the license. https://ch.mathworks.com/support/co...

más de 1 año hace | 0

Respondida
F28379D PMSM Current Control
Offset angle incorrect value will have an effect on the control, since the control is tied to dq refrence framework. Offset valu...

más de 1 año hace | 0

Respondida
How will I simulate a circuit of Bidirectional DC-DC converter fed drive using MOSFETs for electric vehicle system ?
@chandan solanki If you need a system level model for testing out the charging topology a starting place would be EV Reference...

más de 1 año hace | 0

Respondida
Electric Vehicle Model using PMSM
Dakai Hu answered the question in the comment above. Since the question does not specify fidelity and usecase. I wanted to add ...

más de 1 año hace | 0

Respondida
How can I use a Single Phase programmable voltage source in Specialized Power Systems Simulink?
Hello, You can use the controlled voltage source that will allow you to specify the voltage profile either using Simulink logic...

casi 2 años hace | 0

Respondida
逆变器如何和电压或者电流相连。
Hello, Because of my limited language skills. I did not get the question. But, based on the image I am summarizing that you are...

casi 2 años hace | 0

Respondida
Electric vehicle simulation in simscape domain
Hi Ankan, On the first issue, can you share the model to give some more insight. I would suggest at looking at the initializati...

alrededor de 2 años hace | 0

Respondida
Modelling Electric vehicle with dual motor setup.
There are couple of examples that can be used as starting point for putting together two motors on the same shaft that you are l...

alrededor de 2 años hace | 0

Respondida
coupling two induction motor in simscape
There are couple of examples that can be used as starting point for putting together two induction motors on the same shaft that...

alrededor de 2 años hace | 0

Respondida
Distribution line is not making connection with sinusoidal source & d-q based model of induction motor. What is a way to connect the distribution line with them?
Hi Sushant, These are two different modelling environments Simulink and Specialized Power Systems (formerly SimPowerSystems), b...

alrededor de 2 años hace | 0

Respondida
Using a circuit from one file in another
Hi, Its possible to have multiple simscape networks in the same simulink model. In that case we can use Simulink to manually co...

alrededor de 2 años hace | 0

Respondida
Possible mistake in PMSM current_controllers in a demo model
In thi reference example the controller does not take the cross coupling into account for the closed loop control. For closed co...

alrededor de 2 años hace | 1

| aceptada

Respondida
please help regarding temperature measure of a electrical network
Error Simulink is thorwing indicates that the solver does not have enough information to solve the equations. Add an electrical ...

más de 2 años hace | 0

Respondida
Time Delay in Real-time Simulation with Vehicle Dynamics Blockset Interface for Unreal Engine 4
I suspect a hardware issue (GPU/ UDP) that is causing the drift between the real-time platform and game to be large. Is your set...

casi 5 años hace | 0