Pregunta


Is it possible to give a subsystem different outline colors (foreground color different for each port)
Hello everyone, I just wanted to know, whether it is possible to give a subsystem different outline colors. I know I can change...

alrededor de 11 años hace | 0 respuestas | 0

0

respuestas

Pregunta


[Simscape] Why does the thermal liquid pipe calculate incorrect temperatures?
Hello everyone, I am currently trying to build a heat exchanger with the standard elements from the thermal and thermal liqui...

alrededor de 11 años hace | 2 respuestas | 0

2

respuestas

Respondida
Dynamic mask dialogues - change parameters of more than one subsystem
Ok, found the answer and the trick is quite simple: thinking ;) What about using a variable to save the first correct block p...

alrededor de 11 años hace | 0

| aceptada

Pregunta


Dynamic mask dialogues - change parameters of more than one subsystem
Hello everybody, I'm currently using callbacks in parameter masks to switch block choice for configurable Subsystems. So I h...

alrededor de 11 años hace | 1 respuesta | 0

1

respuesta

Respondida
Variant control for variant subsystems with mask parameters?
I think a good description can be found here: http://blogs.mathworks.com/seth/2008/08/13/dynamic-mask-dialogs/

alrededor de 11 años hace | 0

| aceptada

Pregunta


Variant control for variant subsystems with mask parameters?
Hello everybody, I'm currently working a lot with referenced and variant subsystems and I'm wondering whether you could set t...

más de 11 años hace | 2 respuestas | 1

2

respuestas

Pregunta


Dynamic / animated xy graph in simulink possible?
Hello everybody, I have a wall model, where I try to visualize the temperature between the layers. Therefore I intend some k...

más de 11 años hace | 0 respuestas | 0

0

respuestas

Respondida
Erroneous feedback connection involving one or more virtual blocks
Ok, my solution was to put gain-blocks (with factor 1) between every bus-signal and to rename the signal afterwards. Example:...

más de 11 años hace | 2

Respondida
Erroneous feedback connection involving one or more virtual blocks
I even get this error while using 2012b, 2013a and 2013b beta. The model worked in 2012a and I don't know what happened. So ...

más de 11 años hace | 0

Respondida
Is it possible to freely change postions of inputs and outputs of simulink blocks?
Maybe we'll see that in future distributions? Is it the same thing with simscape and related products?

más de 12 años hace | 0

Pregunta


Is it possible to freely change postions of inputs and outputs of simulink blocks?
Hello, I am just wondering, if there is any possiblity to change the positions of inputs and outputs of simulink blocks. I.e....

más de 12 años hace | 3 respuestas | 2

3

respuestas

Respondida
simulink - cascade of (basic cell) blocks
No ideas by anyone?

más de 13 años hace | 0

Respondida
simulink - cascade of (basic cell) blocks
Could the "for each subsystem"-block be a solution? I've currently never worked with that...

más de 13 años hace | 0

Respondida
simulink - cascade of (basic cell) blocks
I have a similar question, since I want to build a NTU heat exchanger, where I can dynamically change the number of units (each ...

más de 13 años hace | 0

Pregunta


signal builder: repeat a signal for n times in one simulation (not to be confused with running in succession)
Hello, is it possible to repeat signals of the signal builder periodically, so that it would be possible to run maybe 6 times c...

más de 13 años hace | 6 respuestas | 0

6

respuestas

Respondida
sample time mismatch
Thanks for the hint. Now it works, after changing sample time of the signal builder block to [0,1] (fixed in minor step).

más de 13 años hace | 1

| aceptada

Respondida
sample time mismatch
Is there any possibilty to debug the system, so that rate transition is not necessary (currently I cannot find the one with "con...

más de 13 años hace | 0

Pregunta


sample time mismatch
after implementing a signal builder instead of single Steps, I get the following message: "Incoming buses to block 'Thermosch...

más de 13 años hace | 4 respuestas | 0

4

respuestas

Pregunta


Store state or signal, if speed or flow is zero
Hello, I am trying to build up tubes for liquids, which handle a bus of volume flow, temnperature, densitiy and heat capacity...

más de 13 años hace | 0 respuestas | 0

0

respuestas