Main Content

Test Two Simulations for Equivalence

Verify model equivalence in normal and SIL simulation mode.

This example shows how to test for equivalence between two models using test harnesses and the test manager. One model runs in normal mode, and a test harness model created from a subsystem runs in software-in-the-loop (SIL) mode.

The equivalence test case in the test manager compares signal output between two simulations to determine equivalence. Signals from the main model and the test harness are set up for logging in this example. The logged signals are used as the equivalence criteria between normal and SIL mode.

Configure the Model

Open the sltestNormalSILEquivalenceExample model.

mdl = 'sltestNormalSILEquivalenceExample';
harnessOwner = 'sltestNormalSILEquivalenceExample/Controller';
open_system(mdl);

Turn on signal logging in the model.

set_param(mdl,'SignalLogging','on','SignalLoggingName','SIL_signals');

Mark the Controller subsystem output and input signals for logging.

ph_controller_in = get_param('sltestNormalSILEquivalenceExample/Controller/In1','PortHandles');
ph_controller_out = get_param('sltestNormalSILEquivalenceExample/Controller','PortHandles');

set_param(ph_controller_in.Outport(1),'DataLogging','on');
set_param(ph_controller_out.Outport(1),'DataLogging','on');
clear ph_controller_in ph_controller_out;

Simulate the model and output the logged signals. The signal data is used as input for the test harness.

out = sim(mdl);

Get the logged signal data.

out_data = out.get('SIL_signals');
control_in1 = out_data.get(2);

Create a Test Harness for SIL Verification.

The command to create the harness will generate code. Switch to a directory with write permissions.

origDir = pwd;
dirName = tempname;
mkdir(dirName);
cd(dirName);
cleanup = onCleanup(@()cd(origDir));
sltest.harness.create(harnessOwner,'Name','SIL_Harness','VerificationMode','SIL');
### Starting build procedure for: Controller
### Successful completion of build procedure for: Controller
### Creating SIL block ...
Building with 'gcc'.
MEX completed successfully.

Build Summary

Top model targets:

Model       Build Reason                                         Status                        Build Duration
=============================================================================================================
Controller  Information cache folder or artifacts were missing.  Code generated and compiled.  0h 0m 18.637s 

1 of 1 models built (0 models already up to date)
Build duration: 0h 0m 31.375s

Open the test harness.

sltest.harness.open(harnessOwner,'SIL_Harness');

Set Up Logging in the Test Harness

Turn on signal logging in the test harness.

set_param('SIL_Harness','SignalLogging','on','SignalLoggingName', 'SIL_signals');

Mark the test harness outport for signal logging to use in the equivalence test case.

ph_harness_out = get_param('SIL_Harness/Controller','PortHandles');
set_param(ph_harness_out.Outport(1),'DataLogging','on');
clear ph_harness_out;

Assign the input data from the simulation to the test harness.

set_param('SIL_Harness','LoadExternalInput','on',...
    'ExternalInput','control_in1.Values');

Create an Equivalence Test Case in the Test Manager

Open the test manager.

sltest.testmanager.view

Create an equivalence test case.

  1. From the test manager toolstrip, click New > Test File.

  2. Specify the test file as testHarnessEquivalence.mldatx. The test manager creates the test file with a new test suite and baseline test case by default.

  3. In the Test Browser pane, select the baseline test case, New Test Case 1, and click Delete.

  4. Select New Test Suite 1.

  5. From the toolstrip, New > Test Case > Equivalence Test.

  6. In the Test Browser pane, right-click the new equivalence test case and select Rename. Name the new equivalence test case SIL Equivalence Test.

Assign the test harness to the equivalence test case Simulation 1.

  1. Expand Simulation 1 and System Under Test.

  2. Click the Use current model button to assign sltestNormalSILEquivalenceExample to Model.

  3. Expand Test Harness.

  4. Click the Refresh button to get an up-to-date list of available test harnesses.

  5. Select SIL_Harness from the Harness menu to use as the System Under Test.

Assign the sltestNormalSILEquivalenceExample model as Simulation 2.

  1. Collapse Simulation 1.

  2. Expand Simulation 2 and System Under Test.

  3. Click the Use current model button to assign sltestNormalSILEquivalenceExample to Model.

  4. Collapse Simulation 2.

Capture the equivalence criteria. Under Equivalence Criteria, click Capture to run the test harness in Simulation 1 and identify the equivalence signal.

Run the Test Case and View the Results

Select SIL Equivalence Test in the Test Browser pane and click Run in the toolstrip. The test manager switches to the Results and Artifacts pane and runs the equivalence test case. The test case passes because the signal comparison between the model and the test harness matches. Expand the results set and select the Controller:1 option button to plot the signal comparison.

close_system(mdl, 0);
clear mdl harnessOwner cleanup control_in1 origDir out out_data;

See Also

Related Topics