Mean (Variable Frequency)
Compute mean value of signal
Library
Simscape / Electrical / Specialized Power Systems / Sensors and Measurements
Description
The Mean (Variable Frequency) block computes the mean value of the signal connected to the second input of the block. The mean value is computed over a running average window of one cycle of the frequency of the signal:
This block uses a running average window. Therefore, one cycle of simulation must complete before the block outputs the computed mean value. For the first cycle of simulation, the output is held constant to the specified initial value.
Parameters
- Initial frequency (Hz)
Specify the frequency of the first cycle of simulation. Default is
60
.- Minimum frequency (Hz)
The minimum frequency value determines the buffer size of the Variable Time Delay block used inside the block to compute the mean value. Default is
45
.- Initial input (DC component)
Specify the initial value of the input during the first cycle of simulation. Default is
0
.- Sample time
Specify the sample time of the block, in seconds. Set to
0
to implement a continuous block. Default is0
.
Inputs and Outputs
Freq
The frequency of the signal.
In
Connects to the signal to be analyzed.
X
The mean value of the signal.
Characteristics
Sample Time | Specified in the Sample Time parameter Continuous if Sample Time = 0 |
Scalar Expansion | Yes, of the parameters |
Dimensionalized | Yes |
Examples
The power_MeanVariableFrequency
model compares the Mean
block to the Mean (Variable Frequency) block for three identical input
signals. It shows that, even if the frequency of the input signals varies during the
simulation, the Mean (Variable Frequency) block outputs correct values.
The model sample time is parameterized by the Ts variable with a default value of 50e-6 s. Set Ts to 0 in the command window to simulate the model in continuous mode.
Version History