rt_UpdateSigLogVars missing in Simulink coder r2014a

It looks like rt_UpdateSigLogVars() is still declared in rt_logging.h but is not defined anymore in rt_logging.c.
Does it mean that this call isn't needed anymore?
Thanks

1 comentario

This might be a very old question, but I am having the same problem now in Matlab R2015a. Just out of curiosity, what did you do to fix this problem?

Iniciar sesión para comentar.

Respuestas (1)

Werner
Werner el 15 de Mayo de 2023
I have the same problem with MATLAB 2015b ... any news on this ?

3 comentarios

Frederic
Frederic el 15 de Mayo de 2023
It turned out that this API wasn't needed anymore for versions greater than 2013
#if (MATLAB_RELEASE < 2014)
rt_UpdateSigLogVars(rtmGetRTWLogInfo(S), rtmGetTPtr(S));
#endif
Werner
Werner el 16 de Mayo de 2023
Thanks so much Frederic for your answer !
So does this mean that I can just remove the call from existing code that I upgrade to MATLAB 2015 or do I have to replace it by somethng else ?
Frederic
Frederic el 16 de Mayo de 2023
Yes, you can remove the call. I don't think there is a replacement call.