Borrar filtros
Borrar filtros

Error compiling Simscape network for model Loss_BuckConverter

1 visualización (últimos 30 días)
Shyam
Shyam el 5 de Nov. de 2021
Editada: Shyam el 6 de Nov. de 2021
I am getting the following error message while running 'Loss_BuckConverter' obtained from matlab file exchange, which was selected as the best pick that week. I would like to run the model. Could you please help in solving the error. Thank you.
Error compiling Simscape network for model Loss_BuckConverter.
Caused by:
['Loss_BuckConverter/Simscape Thermal Model/Thermal Mass (Case)']: Type mismatch for equation. The left hand side of the equation is {[1x1 double], 'C'} and the right hand side of the equation is {[1x1 double], 'K'}. In foundation.thermal.elements.mass (line 33)
T = {[1x1 double], 'C'}
M.T = {[1x1 double], 'K'}

Respuestas (0)

Categorías

Más información sobre Troubleshooting en Help Center y File Exchange.

Etiquetas

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by