How can I connect 3 Simscape ports programmatically

3 visualizaciones (últimos 30 días)
Ferdinand Grimm
Ferdinand Grimm el 14 de En. de 2022
Respondida: Timo Dietz el 14 de En. de 2022
Hello everyone,
Recently I am having a simulink problem:
I would like to connect 3 Simscape Electrical Ports programmatically.
The result should look something like this:
For that I wrote a MATLAB Code that should create the above:
simulink
open_system(new_system('sys'));
% Add Blocks
add_block('nesl_utility/Connection Port','sys/1');
add_block('nesl_utility/Connection Port','sys/2');
add_block('ee_lib/Passive/Capacitor','sys/C');
% Move Blocks
set_param('sys/1','position',[0,0,30,30]);
set_param('sys/C','position',[0,100,30,130]);
set_param('sys/2','position',[0,200,30,230]);
% Find Position
par1 = get_param('sys/1','PortConnectivity');
parC = get_param('sys/C','PortConnectivity');
par2 = get_param('sys/2','PortConnectivity');
pos1 = par1.Position;
posC1 = parC(1).Position;
posC2 = parC(2).Position;
pos2 = par2.Position;
% Connect Blocks
add_line('sys', [pos1;posC1]);
add_line('sys', [pos2;posC2]);
add_line('sys', [pos1;pos2]);
The problem is, that one connection is always missing, and with the above code I get this:
Is there any solution for this?

Respuesta aceptada

Timo Dietz
Timo Dietz el 14 de En. de 2022
Hello,
you can directly connect via the port pin names, instead of using the position information:
add_line('sys', '1/RConn1', 'C/LConn1')
add_line('sys', '2/RConn1', 'C/RConn1')
add_line('sys', '1/RConn1', '2/RConn1')

Más respuestas (0)