Simulink Protected Model and coder.cevel()
Mostrar comentarios más antiguos
I'm trying to create a protected model from a Simulink model contained embedded matlab functions using coder.ceval() to pull in custom C code. When I do, I get an error, "Identical charts with different custom code settings are not supported." There error is pretty cryptic and doesnt point to any particular location. I had to systematically remove bits of my model until I zeroed in on which blocks were causing the error.
Has anybody had any success using coder.ceval in a protected simulink model?
Respuestas (1)
Infinite_king
el 8 de Feb. de 2024
Editada: Infinite_king
el 8 de Feb. de 2024
0 votos
Hi Joel Handy,
To generate a protected model, try setting the dependent source files and header files information separately for each 'MATLAB function' block utilizing 'coder.ceval'.
To possibly resolve the issue follow the below troubleshooting steps,
- In the configuration setting, disable the 'Import custom code'. Refer the following documentation for more information, https://www.mathworks.com/help/simulink/gui/parse-custom-code-symbols.html
- Enable 'Include custom code for referenced models' in configuration settings. Refer the following documentation for more information https://www.mathworks.com/help/simulink/gui/includecustomcodeforreferencedmodels.html
- For each 'MATLAB function' block, include the dependent source files and headers. Refer the following documentation for more information https://www.mathworks.com/help/coder/ug/customizing-the-post-code-generation-build-process.html
Hope this is helpful.
Categorías
Más información sobre Deployment, Integration, and Supported Hardware en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!