Load Flow Analysis employing Solid State Transformer
    11 visualizaciones (últimos 30 días)
  
       Mostrar comentarios más antiguos
    
This is a simple 3 bus network where Solid state transformer is connected between bus 1 and bus 3. The model of SST is working perfectly but whenever I run the load flow, bus 2 (loads connected at SST) is being ignored by prompting a message 'The following subnetworks have been ignored because they contain no swing bus'. I don't know whether it is due to detail model of SST employing multiple power electronic device in between or due to High Frequency transformer in between, does anybody have idea regarding this ? Thanks !

1 comentario
  Feng
 el 24 de Oct. de 2025 a las 1:03
				Where can we download the model to have futher analysis? Thanks!
Respuestas (1)
  Sabin
    
 el 30 de Dic. de 2022
        
      Editada: Sabin
    
 el 30 de Dic. de 2022
  
      I believe the main issue here is level of fidelity of the SST. It looks like detailed power electronics and transformer are employed but that’s a bit in contradiction with the definition of load flow analysis. I suggest implementing the SST in a more abstract way. 
0 comentarios
Ver también
Categorías
				Más información sobre Magnetic Elements en Help Center y File Exchange.
			