Error : Action subsystem have more than one sample time

5 visualizaciones (últimos 30 días)
Mohd Hazny Aziz
Mohd Hazny Aziz el 27 de Sept. de 2011
Assalamualaikum & Hi all,
I have a problem with action subsystem, when i want to build a model in a real-time process. the matlab error says that some block in the Action Subsystem have more than one sample time.
What does it means anyway?..i'm so confuse..can anyone help me

Respuesta aceptada

TAB
TAB el 27 de Sept. de 2011
All blocks in an Action Subsystem must run at the same rate as the driving block. You can achieve this by setting each block's sample time parameter to be either inherited (-1) or the same value as the driving block's sample time.
  1 comentario
TAB
TAB el 27 de Sept. de 2011
Please refer
http://www.mathworks.in/help/toolbox/simulink/slref/actionport.html