Borrar filtros
Borrar filtros

Simcape onramp getting the error of block value

2 visualizaciones (últimos 30 días)
Sudchai Boonto
Sudchai Boonto el 8 de Abr. de 2022
Comentada: PranayReddy B el 19 de Mayo de 2022

Respuestas (1)

Ganesh Gudipati
Ganesh Gudipati el 11 de Abr. de 2022
Hi,
The errorMultiple Solver Blocks connected to physical network. Each physical network must be connected to exactly one Solver Configuration block” generally arises when there are multiple solver blocks connected to the network.
I tired to reproduce the issue from my end.
In the first picture, notice that there two Solver Configuration blocks which causes the error. And it can be solved by removing one of the Solver blocks. But in the screenshot attached to the question I could see only one solver block. Check if the blocks are overlapped. If the issue is not solved, try to remove all the connections, and reconnect them.
  2 comentarios
Sudchai Boonto
Sudchai Boonto el 13 de Abr. de 2022
Thank you for you helping.
My problem was not the issue of the Solve block but the isothermal liquid properies as show in the figure below. The volumetric fraction of entrained ... must set to 0.
PranayReddy B
PranayReddy B el 19 de Mayo de 2022
thanks alot
you saved my entire day

Iniciar sesión para comentar.