Battery SOC is showing 0 reading in scope while discharging
1 visualización (últimos 30 días)
Mostrar comentarios más antiguos
i am trying the given model but i am not getting proper SoC graph its showing 0 throughout the execution the model, graph and setting of battery are given below kindly give feedback what actually wrong with the settings thanks
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1066550/image.jpeg)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1066555/image.jpeg)
![](https://www.mathworks.com/matlabcentral/answers/uploaded_files/1066560/image.jpeg)
0 comentarios
Respuestas (1)
Xiangchun
el 20 de Oct. de 2023
Hi Armaghan,
The SOC physical signal from the Battery (Table-Based) block goes through PS-Simulink Converter before it becomes a Simulink signal that is suitable for display on the Scope. From the screenshot, it appears that there are two PS-Simulink Converters for the SOC signal converstion. Only one is needed. Please double check the model and connections to verify if that is indeed the case.
Best wishes,
Xiangchun