simulink asynchronous machine rotor parameters
Mostrar comentarios más antiguos
Hello, in the model of the asynchronous machine the rotor currents(ir_,ir_b,ir_c), voltages(v_ra,v_rb, v_rc) and inductances are already referred to the stator or not? I mean the values in the simulink output of the block containing the measurement signals. Thanks
Respuestas (1)
Sabin
el 12 de Ag. de 2025
0 votos
In the Induction Machine Wound Rotor block, the rotor circuit is referred to the stator. Therefore, when you use the block in a circuit, refer any additional circuit parameters to the stator.