Borrar filtros
Borrar filtros

Simulink.B​lockDiagra​m.arrangeS​ystem does not work inside library

2 visualizaciones (últimos 30 días)
Manuel K
Manuel K el 30 de Nov. de 2022
Editada: Manuel K el 1 de Dic. de 2022
Hello,
I'm using the command:
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true');
to sort and rearrange the blocks inside a masked subsystem. This worked fine until I converted this subsystem into a library block.
Now this command does nothing and the internal structure remains cluttered and unreadabel. Because this blocks heavily modifies itself, I can't establish a pleasant alignment beforehand.
Is there any way to get this working?
  4 comentarios
Fangjun Jiang
Fangjun Jiang el 30 de Nov. de 2022
Sorry, to be acurate, for the library block, I shall refer it as "is the LinkStatus inactive".

Iniciar sesión para comentar.

Respuestas (1)

Fangjun Jiang
Fangjun Jiang el 30 de Nov. de 2022
I've tried it. You need to disable the library link first.
set_param(gcb,'LinkStatus','inactive')
Simulink.BlockDiagram.arrangeSystem(gcb,FullLayout='true')
  2 comentarios
Manuel K
Manuel K el 1 de Dic. de 2022
Although that's working, I don't want to keep the 'LinkStatus' in the 'inactive' state.
(Restoring it isn't possible because the local instance has different blocks inside, which will get deleted.)
Manuel K
Manuel K el 1 de Dic. de 2022
Editada: Manuel K el 1 de Dic. de 2022
Since the command only works the first time after placing the library-block (as mentioned in my comment above), my workaround is the following:
Everytime I need to change / update a setting inside the mask of the librry-block, I place a new instance and delete the old one.

Iniciar sesión para comentar.

Categorías

Más información sobre Simulink Environment Customization en Help Center y File Exchange.

Productos


Versión

R2022b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by