Borrar filtros
Borrar filtros

How to use run-time tunable parameter for Constant Volume Chamber (G)

3 visualizaciones (últimos 30 días)
Stian
Stian el 8 de Mayo de 2023
Respondida: Akshat Dalal el 7 de Sept. de 2023
When you use e.g. a DoubleActing Actuator (IL) in Simulink/SimScape, you can select that the initial position displacement parameter should be run-time tunable from a dropdown menu, instead of compile-time tunable.
How can you make a parameter for the initial pressure of the gas to be run-time tunable for a "Constant Volume Chamber (G)"?
Here the there is no option to change from compile-time to run-time.
Exported c++ code has this value hardcoded according to the current value of the parameter in the Workspace.
  1 comentario
Yifeng Tang
Yifeng Tang el 10 de Mayo de 2023
I think it's do-able. Try this first: make this InitialPressure a Simulink Parameter in the Model Workspace, instead of MATLAB base workspace variable. Will you see it available in the generated code, instead of hard-coded?

Iniciar sesión para comentar.

Respuestas (1)

Akshat Dalal
Akshat Dalal el 7 de Sept. de 2023
Hi Stian,
I understand you would like to make some of the block parameters run-time tunable. You could refer to the following documentations for the same:
  1. https://in.mathworks.com/help/releases/R2021a/sldrt/ug/tune-block-parameters-and-matlab-variables.html
  2. https://in.mathworks.com/help/simscape/ug/specify-and-change-a-run-time-configurable-parameter.html
Hope this helps.

Categorías

Más información sobre Run-Time Parameters en Help Center y File Exchange.

Productos


Versión

R2021a