for PI feedback controller with un-unity feedback, final values is off

4 visualizaciones (últimos 30 días)
I have a second-order transfer function, and I am using integral control, but the final value will not settle at the input level (step).
My attempt is below
--------------------------------------------------
s = tf('s');
G = tf(1, [1, 1.4, 1]);
>> ki=1; % I-gain
Dc=ki/s; % I-control with integral gain ki
step(feedback(Dc*G,0.5,-1)); % the 0.5 is what I have in the feedback path and G*Dc is the gain in the forward path.
------------------------------------------------------------
The output will not settle at 1. Any suggestions

Respuesta aceptada

Sam Chak
Sam Chak el 18 de Oct. de 2023
You can fix the issue by scaling the step input to match the gain in the feedback path (H) in order to eliminate the steady-state error.
s = tf('s');
Gp = tf(1, [1, 1.4, 1]);
ki = 1;
Gc = ki/s;
H = 0.5;
Gcl = feedback(Gc*Gp, H)
Gcl = 1 ----------------------- s^3 + 1.4 s^2 + s + 0.5 Continuous-time transfer function.
scaledIn = H; % scale the step input to match H
tFinal = 30;
step(scaledIn*Gcl, tFinal)
  2 comentarios
Abdulaziz Abutunis
Abdulaziz Abutunis el 18 de Oct. de 2023
Movida: Sam Chak el 19 de Oct. de 2023
Thank yo Sam for your response.
I thought there will be some command used to account for that rather than simply scaliing the input.
Thank you again
Aziz
Sam Chak
Sam Chak el 19 de Oct. de 2023
You are welcome, @Abdulaziz Abutunis. Don't forget to 'click-accept' the answer, and feel free to post new questions related to transfer function design problems.

Iniciar sesión para comentar.

Más respuestas (0)

Categorías

Más información sobre Software Development Tools en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by