for PI feedback controller with un-unity feedback, final values is off
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Abdulaziz Abutunis
el 17 de Oct. de 2023
Comentada: Sam Chak
el 19 de Oct. de 2023
I have a second-order transfer function, and I am using integral control, but the final value will not settle at the input level (step).
My attempt is below
--------------------------------------------------
s = tf('s');
G = tf(1, [1, 1.4, 1]);
>> ki=1; % I-gain
Dc=ki/s; % I-control with integral gain ki
step(feedback(Dc*G,0.5,-1)); % the 0.5 is what I have in the feedback path and G*Dc is the gain in the forward path.
------------------------------------------------------------
The output will not settle at 1. Any suggestions
0 comentarios
Respuesta aceptada
Sam Chak
el 18 de Oct. de 2023
You can fix the issue by scaling the step input to match the gain in the feedback path (H) in order to eliminate the steady-state error.
s = tf('s');
Gp = tf(1, [1, 1.4, 1]);
ki = 1;
Gc = ki/s;
H = 0.5;
Gcl = feedback(Gc*Gp, H)
scaledIn = H; % scale the step input to match H
tFinal = 30;
step(scaledIn*Gcl, tFinal)
2 comentarios
Sam Chak
el 19 de Oct. de 2023
You are welcome, @Abdulaziz Abutunis. Don't forget to 'click-accept' the answer, and feel free to post new questions related to transfer function design problems.