Borrar filtros
Borrar filtros

Step Response Initial Value Unchangeable?

5 visualizaciones (últimos 30 días)
Edward Robson
Edward Robson el 27 de En. de 2024
Respondida: Sam Chak el 28 de En. de 2024
Hello,
On control system designer there is a box shaded out for the initial value of the step response plot? Is it possible to change this value - or why has it been included but greyed out?
Thank you
  2 comentarios
VBBV
VBBV el 28 de En. de 2024
Try changing the Design requirement type option from menu bar above to different one. Currently it is step response bound
See if the initial value parameter field box is activated
VBBV
VBBV el 28 de En. de 2024
Further, the final value and rise time seem to be set to same value, try changing them too something more meaningful

Iniciar sesión para comentar.

Respuestas (1)

Sam Chak
Sam Chak el 28 de En. de 2024
In the "Design Requirements" documentation, it is explained that the fields are greyed out because step response plots always use an Initial value and a Step time of 0. Therefore, there are no options available in this menu. Generally, the initial value shouldn't affect the controller tuning for linear systems. You can find more information in the following link:

Productos


Versión

R2023b

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by