AUTOSAR Classic System Composer Client Server Interfaces
7 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
I am trying to create an arcitecture on System Composer, want to design client server interfaces. Is there a limitation for AUTOSAR Classic plathform, because I am receiving errors while doing this. The error says
Unable to export model 'TestModel' to AUTOSAR architecture. Consider removing the following element(s) from the architecture:
Caused by:
- Client and server ports are not supported in Classic AUTOSAR architectures.
0 comentarios
Respuestas (1)
Feimi
el 15 de Mzo. de 2024
Hi Melih,
This is a limitation that Classic AUTOSAR architecture does not support client/server ports as of MATLAB 2023b. For a complete list of the limitations in exporting from software architecture to AUTOSAR architectures, please find the documentation here:
Feimi
2 comentarios
Feimi
el 16 de Abr. de 2024
Hi Melih,
In MATLAB R2023b and later versions, you can use architecture data editor with AUTOSAR Classic platform mapping to edit NV and MS interfaces:
https://www.mathworks.com/help/autosar/ref/architecturaldataeditor.html
For CS interfaces, since they cannot be modeled in AUTOSAR Classic Architecture models, they need to be configured in the Simulink model. Please refer to this article on how to configure C-S communication in a Simulink model:
Feimi
Ver también
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!