Parallel tool (parfor) and COM objects
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Ahmadreza
el 17 de Abr. de 2024
Comentada: Ahmadreza
el 18 de Abr. de 2024
Dear All,
I am trying to optimize the run time of my model by using the parallel tool. In my model, I am working with a COM object as follow:
iphreeqc = actxserver('IPhreeqcCOM.Object'); % calling the COM object
iphreeqc.LoadDatabase('database\phreeqc.dat'); % adding the prefered database to the COM object
n = 100;
Temp = [1:1:100];
R = 0.082057366080960;
OUTPUT = cell(100,1);
parfor i=1:n
IPCstringCell= {'SOLUTION 1', ...
['-temp ', num2str(Temp(i))], ...
'-pressure 10', ...
'-units mmol/L', ...
'Na 0',...
'Cl 0',...
'-water 1', ...
'pH 7 charge',...
'Gas_phase',...
'-pressure 10',...
['volume ',num2str(R*(Temp(i)+273.15)/10)],...
'fixed_volume',...
['-temp ',num2str(Temp(i))],...
'H2(g) 10',...
'SELECTED_OUTPUT', ...
'-saturation_indices H2(g)', ...
'sim true',...
'step true',...
'soln true', ...
'pH true', ...
'-equilibrium_phases H2(g)',...
'-molalities H2', ...
'state false', ...
'time false', ...
'distance false'};
IPCstring = sprintf('%s\n', IPCstringCell{:});
iphreeqc.RunString( IPCstring );
output = iphreeqc.GetSelectedOutputArray;
OUTPUT{i,1} = output;
end
However, I am facing with the below error:
It seems I cannot use dot (.) index to work with the iphreeqc object in the above code. In this case, what should I do?
Kind regards,
Ahmad
2 comentarios
Mario Malic
el 17 de Abr. de 2024
Try to open your COM application within parfor loop and see what happens.
Respuesta aceptada
Mario Malic
el 17 de Abr. de 2024
Editada: Mario Malic
el 17 de Abr. de 2024
It's not about time consumption.
Opening the application within parfor loop gives each worker its own instance of application so they can interact with it. This solved the question.
If you initialize COM instance outside of parfor, it can't be "copied" to workers' workspace (I am unable to explain why, there is a logical reason for sure). Regardless, it is not sensible to have one instance of program for workers to operate on asynchronously.
0 comentarios
Más respuestas (1)
Edric Ellis
el 18 de Abr. de 2024
The general approach to fixing cases where a variable is needed inside parfor, but cannot be directly sent there, is to use parallel.pool.Constant. You give the Constant constructor a function handle which gets run once on the workers to build the COM object, and then inside parfor, you access the .Value field of the Constant which has the value that got built.
Ver también
Categorías
Más información sobre Parallel for-Loops (parfor) en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!