Errors in feedback control after setting the input of a prismatic joint to motion/provided by input
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
석준
el 5 de Ag. de 2024
Comentada: Yifeng Tang
el 7 de Ag. de 2024
Hello, I am currently controlling the prismatic joint actuators of a Stewart platform using Simulink. I have set the input to motion/provided by input in order to change the position of the eight actuators over time. However, when I try to perform feedback control in the simulation, I encounter errors as shown in the image below. Feedback control works when the input is set to force, but why do these errors occur when the input is set to motion? If anyone knows the answer, I would be very grateful for your help.
0 comentarios
Respuesta aceptada
Divyanshu
el 6 de Ag. de 2024
A possible reason for such errors is that an algebraic loop is formed in your model when input is set to motion.
For more information about identification and removal of algebraic loops have can refer the following links:
Hope it helps!
2 comentarios
Yifeng Tang
el 7 de Ag. de 2024
Unit Delay may work just fine, or create some numerical inefficiency, depending on the nature of the rest of your system. You may check the step sizes and solver resets using Solver Profiler and see if that's the case. One potential concern is mixing discrete block (Unit Delay) with continuous ones (Simscape). If indeed that gives you issues, consider replace the Unit Delay with a Transfer Fcn block, with a reasonable time constant.
Más respuestas (0)
Ver también
Categorías
Más información sobre Assembly en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!