Error during FFT analyzer is Simulink
2 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
On this picture you can see my simulink circuit and the error I get when i try to run the FFT analyzer through the powergui. I have already unticked the "Single simulation output" in the "Configuration parameters", and saved the data in workspace.
What does this error message mean? I am running on Matlab R2024a.
1 comentario
Respuestas (1)
Pramil
el 7 de Oct. de 2024
Editada: Pramil
el 7 de Oct. de 2024
Hi Asmund,
I have faced a similar issue while using MATLAB R2024a. The issue seems to stem from the output variable being of type "Dataset".
What worked for me was to run the model and then convert the output variables into type "struct".
You can use the following code to do the same:
function newlogsout = Dataset2Struct(logsout)
newlogsout.time = logsout.getElement(1).Values.Time;
newlogsout.blockName = logsout.getElement(1).BlockPath.getBlock(1);
for i=1:logsout.numElements
newlogsout.signals(i).values = logsout.getElement(i).Values.Data;
newlogsout.signals(i).label = logsout.getElement(i).Values.Name;
newlogsout.signals(i).dimensions = 1;
end
end
After this, you can select the struct variables within "FFT Analyzer" and it should work just fine.
Hope it helps.
0 comentarios
Ver también
Categorías
Más información sobre Electrical Sensors en Help Center y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!