Some Constant blocks not tunable in Simulink External Mode
Mostrar comentarios más antiguos
I'm running 2014a and I am using a Simulink model in External run mode. I have a few constant blocks I'd like to change the value of however they aren't all tunable during run time. For instance, Constant1 and Constant2 are connected to a Subsystem and Constant1's block properties are greyed out during runtime however Constant2's block properties I can change during runtime. They are virtually identically blocks wrt properties. Not sure what's going on here.
3 comentarios
Mike Buba
el 23 de Oct. de 2021
Hi, I have the same issue with the Simulink model in External run mode for Matlab 2018a. Were you able to find a solution? Some constants are tunable and some are not. And I just copy/paste blocks
Thomas Marullo
el 23 de Oct. de 2021
Mike Buba
el 24 de Oct. de 2021
I noticed the not tunable constants were directly or indirectly, via subtract block (reference - feedback), connected to the PID Controller block.

When I implemented my PI block (similar to as it is under the PID Controller's mask), I could tune them.
Respuestas (1)
Sebastian Castro
el 14 de Mayo de 2015
0 votos
Are those constant blocks using hard-coded numerical values or are they variables (either numeric or Simulink.Parameter objects?)
- Sebastian
2 comentarios
Thomas Marullo
el 14 de Mayo de 2015
Editada: Thomas Marullo
el 14 de Mayo de 2015
Sebastian Castro
el 14 de Mayo de 2015
Strange... so both "Structure" and "Integrator" are MATLAB structures, then?
Which of those blocks in your screenshot are the constant blocks in question, and what do they feed into?