MATLAB Simulink Task 5 Power Systems Simulation Incorrect Output Description
Mostrar comentarios más antiguos
I'm working on the MATLAB Simulink Power Systems Simulation Onramp, specifically Task 5. I changed the Wye-Connected Load block component structure to Series RL and set the default value to 12∠0° (A) for inductive reactive power, as required. I also used the filter from the previous task to extract the reactive power from the Q port of the Power Sensor and connected the filtered measurement to the Signal Assessment block. However, I still receive an incorrect output error.
Could anyone help identify what might be wrong?

Respuestas (1)
Cris LaPierre
el 22 de Feb. de 2025
0 votos
This is happening because the default value for one of the Wye-Connected Load block parameters has changed in R2024b.
Under Parasitics, change the Parasitic parallel conductance to 0. Keep the units as 1/Ohm.
Now submit.
1 comentario
Categorías
Más información sobre String en Centro de ayuda y File Exchange.
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!
