- Wrap each filter block and output block in ‘nonreusable atomic subsystems’.
- Enable ‘Late Inline’ to prevent Simulink Coder optimizations from changing the execution order.
- Group the Filter and Outport Blocks:
- Select Filter 1 and Filter 2, then right-click → Create Subsystem.
- Do the same for the Outport block.
- You should now have ‘Filter_Subsystem’ and ‘Outport_Subsystem’.
- Double-click each subsystem → Block Parameters.
- In the Code Generation tab: Function packaging → Nonreusable function
- Inline → Apply ‘Late Inline’ via MATLAB scripting in the command line:
- Go to Model Configuration Parameters → Simulation Order.
- Set the execution order so that: ‘Filter_Subsystem’ executes before ‘Outport_Subsystem’.
- This guarantees all filtering calculations are completed before updating the Outport.