A simple series system's simscape fluid simulation problem

Why does a system in Simscape Fluid, consisting of components like compressors, turbines, and heat exchangers connected in series, result in all component outlets reaching the outlet pressure when the system exit has a defined pressure Reservoir during steady-state simulation? How can different high and low pressures be transmitted between components? I want the system pressure to vary between components, with the exit being the lowest. Why does the gas pressure at the compressor outlet suddenly drop from the desired pressure to the exit pressure?

1 comentario

it's most likely the parameters in the components and the way the components are driven that's leading to the phenomenon you saw. When modeling with compressors, turbines and heat exchangers, it's a good idea to build test harness models for each component before putting them together. Do you have harness models that you can share and verify the parameters?

Iniciar sesión para comentar.

Respuestas (0)

Categorías

Más información sobre Thermal Liquid Library en Centro de ayuda y File Exchange.

Productos

Versión

R2024a

Etiquetas

Preguntada:

HAN
el 25 de Abr. de 2025

Comentada:

el 30 de Abr. de 2025

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by