Borrar filtros
Borrar filtros

%<BaseSampleTime> variable not available in simulink model-tlc file?

2 visualizaciones (últimos 30 días)
I am trying to create a simulink block that should depend on the base-sample-rate of the model. I tried to put the following in the model-block-tlc file:
%if %<BaseSampleTime> > 0.003
adc1_sum = 0;
for (int i=0; i<8; i++ ) {
adc1_sum += Get_ADC_Value(11);
}
%else
adc1_sum= Get_ADC_Value(11)*8;
%endif
But I get: Undefined identifier BaseSampleTime
Is there a way to determine this value in the models tlc-file? (apart from creating a variable when this value is in scope?)
Thanks in advance, Sietse

Respuesta aceptada

Drew Davis
Drew Davis el 10 de Jun. de 2015
I do not know of any TLC function to get the base sample time of the model. There is however a list of TLC sample time functions that you may find useful. For instance, the function 'LibBlockSampleTime(block)' allows you to access the sample time of the block.

Más respuestas (0)

Categorías

Más información sobre Target Language Compiler en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!