Hello,
I am trying to use DAQ toolbox to measure microphone Array data using NI USB 9234.
In LabVIEW, I configure the device using sound pressure measurement mode.
But, I don't know how to do that in MATLAB DAQ toolbox.
My code is:
clc;
clear all;
i=0;
ai=analoginput('nidaq','Dev1');
chan=addchannel(ai,1);
set (ai, 'SampleRate', 1700);
set(ai.Channel, 'UnitsRange', [0 135]); /* tried it in both volts range and db range*/
set(ai.Channel, 'Units', 'dB');
set(ai,'SamplesPerTrigger',inf);
%%start acquisition
start(ai);
while isrunning(ai)
[data,time]=getdata(ai,1);
i=i+1;
data1(i,1)=data;
end
stop(ai);
Data that's being saved seems to contain only noise. I don't see any sound data i it.
It would be great if someone could tell me how to acquire sound data using the toolbox.
Thanks, Haritha
1 comentario
Atiqah Selamat
el 12 de Jun. de 2013
hi
how you take out data from your recording? I also have problem with that
tq
Respuestas (2)
Manisha
el 13 de Feb. de 2012
Hi Haritha,
NI 9234 has built-in IEPE excitation circuitry. Is your microphone IEPE compliant?
If yes, you can use the new feature added in session based interface for your microphone. R2012a pre-release has added a new specialized measurement type called 'Microphone'. This will turn on the IEPE excitation on your device and thus return meaningful results
You may need to modify the following code:
s = daq.createSession('ni');
s.addAnalogInputChannel('Dev1', 0, 'Microphone');
s.Channels.Sensitivity = 0.037; %Set the microphone's Sensitivity to the value specified in the sensor's data sheet in v/Pascals.
[data,time] = s.startForeground();
Hope that helps,
Manisha
2 comentarios
Atiqah Selamat
el 12 de Jun. de 2013
i am using this code but do not how to check where it did save my recording.
Vinh Dang
el 5 de Mzo. de 2015
Hello, In my application, I have a cDAQ configuration with AI modules 9234 (for accelerometers), 9237 (for pressure and load cell) and 9215 (for proximity and temperature). All modules are put in one chassis cDAQs-9178. What is the valid sampling rate for this?