I have a medium sized Simulink project using Configuration Reference to tie all the submodels (Model Reference) to one Configuration set. Is there a way to change the configuration parameters from the command line using set_param? I get the error:
A configuration set reference does not allow writing to parameters in the source configuration set
Respuestas (1)
Tiago Grossinho
el 18 de Jul. de 2017
Hello,
You probably have your question answered 1 year later, but for reference, I found my answer in the following page:
Chapter " §Change Values in a Referenced Configuration Set". Indeed, if you " Get" the config set which corresponds to the active one in your model, the set_param operation will immediately set the value in the model. My example:
>> get_param('model_name','RTWCAPISignals')
ans =
on
>> cref=getConfigSet('model_name','Reference');
>> cset = cref.getRefConfigSet;
>> set_param(cset,'RTWCAPISignals','off');
>> get_param('model_name','RTWCAPISignals')
ans =
off
Hoping it may help someone in the future, or even myself when I forget it one day! :)
2 comentarios
Gergely Takacs
el 9 de Mayo de 2022
Thank you for the tip. Not entirely user friendly to figure this out:)
Krishna Akella
el 28 de Oct. de 2022
Thanks, it helped me today!