warning about optimset and using optimoptions

1 visualización (últimos 30 días)
Snoopy
Snoopy el 20 de Nov. de 2017
Respondida: Xuan Li el 23 de Mzo. de 2018
Hi, I use the fminunc function and the optimset as
options = optimset('GradObj','on','MaxFunEvals',1000,'MaxIter',1000,'Display','iter','TolFun',1e-100,'TolX',1e-100,'Algorithm','quasi-newton');
[B_hat_so,fval,exitflag,output,GradObj,hessian] = fminunc(@(B_true)exerciseeightpartonefunction(y,X,Z,B_true,W_hat,N_obs,N_par_X),B_ig,options);
I receive the following warning
Warning: Your current settings will run a different algorithm ('quasi-newton') in a future release. Either use optimoptions to set options (recommended), or set option Algorithm to 'trust-region' using optimset.
> In throwFminuncGradObjandLargeScaleWarning (line 18) In fminunc (line 170)
What is it that I can do to get rid of this warning? How should I change my code above? Thanks.

Respuesta aceptada

Star Strider
Star Strider el 20 de Nov. de 2017
Your best option is in the error message:
set option Algorithm to 'trust-region' using optimset.

Más respuestas (1)

Xuan Li
Xuan Li el 23 de Mzo. de 2018
need to 'cd' to directory that you save costFunction()