hello, I'm trying to run a simulink model using fundamental blocks from Simscape\Power system library but I'm getting an error: the following inductors... are connected to the following voltage source. What does that mean and how can I fix it? Thanks

Respuestas (1)

Sabin
Sabin el 12 de Ag. de 2025
It looks like you’re using Specialized Power Systems. This is because an ideal voltage source in a loop with only inductors (or an ideal current source in a loop with only capacitors) can lead to an infinite current or voltage change, which is not physically realizable. You can place a large resistor between the inductors and the ground. Start with 1e6 ohms. Check the current going through the resistor and if above 1% increase the resistor value. The simulation will be more accurate with a larger resistor, but the model will be slower.