Why do I encounter an error message when attempting to plot discharge characteristics in the Battery block with Simscape Power Systems Specialized Technology?
3 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
MathWorks Support Team
el 2 de Jul. de 2018
Respondida: MathWorks Support Team
el 2 de Jul. de 2018
Why do I encounter an error message when attempting to plot discharge characteristics in the Battery block with Simscape Power Systems Specialized Technology?
I am simulating a battery model with temperature effects and I encounter the following error message when I attempt to plot the discharge characteristics:
Error evaluating 'MaskDialog' callback of Battery block (mask) 'modelName/Battery'.
Callback string is 'BatteryCback(gcb,0)'
Value must be a 1x2 vector of numeric type in which the second element is larger than the first and may be Inf
Respuesta aceptada
MathWorks Support Team
el 2 de Jul. de 2018
This error is most likely caused by a simple oversight of not specifying correct battery parameters in the "Temperature" tab. The battery parameters specified in the "Parameters" and "Discharge" tabs are valid for the nominal ambient temperature T1. Under the "Temperature" tab, a second temperature value T2 is specified and corresponding discharge parameters need to be entered.