Simulink Design Verifier - No-Test Case

2 visualizaciones (últimos 30 días)
Shivaputra Narke
Shivaputra Narke el 18 de Oct. de 2018
Comentada: Shivaputra Narke el 12 de Nov. de 2018
Hi,
I am running Design Verifier to generate test cases. After execution, I get below response,
"Test generation completed normally."
16/22 objectives are proven unsatisfiable. 6/22 objectives are satisfied - no test case.
..."
But no test case is generated. However, when I run verifier on simple model, it actually generate test cases. Does anyone know the reason behind this behavior ?
Thanks in advance

Respuestas (1)

Prahladavaradan Sampath
Prahladavaradan Sampath el 25 de Oct. de 2018
It appears that the model is mostly dead (16 out of 22 objectives) -- this is what "unsatisfiable" indicates. The "Satisfied - no test case" status seems to indicate that you are running SLDV on a model with no in-ports. Could you please confirm?
Could you also indicate which version of MATLAB you are using?
  3 comentarios
Prahladavaradan Sampath
Prahladavaradan Sampath el 11 de Nov. de 2018
Would it be possible to share a model for investigation?
Have you tried analyzing this model on a more recent release? (18b is the latest release)
Shivaputra Narke
Shivaputra Narke el 12 de Nov. de 2018
I will check on 2017b. (I dont have latest version with me right now). If it will not work then I will try to share my model with you.