How can I control signal logging in referenced models?

AFAIK, the only way to control signal logging in a referenced model is by right clicking on the model block and pulling up the Model Reference Signal Logging dialog. Is there a way to control signal logging in the referenced model programatically? Can it be done through model arguments so as not cause a rebuild?

Respuestas (2)

Vieniava
Vieniava el 26 de En. de 2011
Try this:
Z=get_param('YourModel/BlockName','PortHandles');
set_param(Z.Outport, 'DataLogging', 'on');
Where: YourModel is your simulink model name and BlockName is name of block which output signal you'd like to log.

1 comentario

Paul
Paul el 27 de En. de 2011
I don't think this can work when the block in question is a Model Reference and I'm trying to control the logging of signals inside the referenced model.

Iniciar sesión para comentar.

Vieniava
Vieniava el 27 de En. de 2011
Phisically go to the block inside referenced model. Next find a handle to this block via
H=get_param(gcb,'Handle);
then
Z=get(H,'Porthandles');
set_param(Z.Outport, 'DataLogging', 'on')
it should work now.

1 comentario

Paul
Paul el 27 de En. de 2011
This would work for one reference, but doesn't provide independent control over multiple references to the same model, such as can be achieved using the Model Reference Signal Logging dialog.