No simlog variable for power loss analysis

I am trying to estimate the dissipated power in the rectifiers and converters in my Simulink model. I have removed all algebraic loops and get no errors (only 3 warnings) when I run sim(model). I have all of the right settings for simulation data-logging and the sim command definitely simulates the model. However, at the end of it there is no simlog variable in my workspace. I have tried to use the command line to view it and that returns 'undefined function or variable'. My Matlab version is R2016b. Please let me know if there is something I'm missing that's causing this.
Thanks

Respuestas (1)

Sabin
Sabin el 13 de Dic. de 2024

0 votos

Two things you can check:
  1. In Configuration Parameters/Simscape the ‘Log simulation data’ is not set to ‘None’.
  2. If ‘Log simulation data’ is not set ‘None’ check in Solver Configuration -> Data Import/Export if the Parameter ‘Single simulation output’ is enabled or disabled. If ‘Single simulation output’ is enabled then you will have a single object as output, by default called out. In this situation to access the simlog you need to access out.simlog.