In the Simulink model that I'm developing, I'm using some Lookup Table Dynamic blocks. When I try to compile the model, the following message appears:
"Error reported by S-function 'sfix_look1_dyn' in '.../DLUT_manager/DLUT_pot1': Breakpoint and table port dimensions must be specified, they cannot be back-inherited. Recommendation: specify breakpoint port or table port dimensions using upstream blocks"
Where can I specify table port dimensions or breakpoint port?
Thank you
Respuestas (1)
Kaustubha Govind
el 29 de Ag. de 2012
0 votos
From the error, it appears that Simulink is unable to determine the dimensions of the 'xdat' and 'ydat' inputs to the Lookup Table Dynamic block. I would recommend inserting a Signal Specification block before each of the two inputs and specify their respective dimensions in the Signal Specification block dialog parameter "Dimensions".