USRP E312 test connection
5 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
when I click test connection in USRP E312 set up it says that "the Test data path between host and RF card" fails? What is this error? and how I can solve this issue ?
0 comentarios
Respuestas (1)
Gavin Grant
el 11 de Nov. de 2019
Hi Huyam,
May I ask if you have loaded a custom bitstream onto the USRP E312 device? If so, this would affect the data path and the test would fail. I would advise you to download the default SD card image to the device in the Hardware Setup App, then re-run the test.
If the issue persists, please let us know so we can debug further.
Kind regards,
Gavin
2 comentarios
Gavin Grant
el 11 de Nov. de 2019
Editada: Gavin Grant
el 11 de Nov. de 2019
Huyam,
I assume you are using the Hardware Setup App to perform setup of your E312 device? If so, on the Select a Drive and Write Firmware pane, you can format your SD card and load it with the default SD card image (including default bitstream) by clicking the Write button.
Otherwise, you can format and write the SD card manually by following the steps in Manual Host-Radio Hardware Setup.
If you have any further questions, please do not hesitate to get in touch.