"duration" function in stateflow using fixed-point datatype for time

3 visualizaciones (últimos 30 días)
Renish Ramegowda
Renish Ramegowda el 24 de En. de 2020
Comentada: stozaki el 30 de En. de 2020
I created an mpt.parameter for a time variable. Since time is in ms, I assigned data type as fixdt(0,16,0.001,0)
time_s = mpt.Parameter;
time_s.CoderInfo.Alias = 'Ts';
time_s.Description = 'Time in ms';
time_s.DataType = 'fixdt(0,16,0.001,0)';
time_s.Unit = 's';
time_s.Value = 0.5;
Now in one of my stateflow transition between states, I need to use this time variable. i.e: [duration(t > 20) > time_s]
Matlab thowrs error as below:
In fi > non-fi, or non-fi > fi, the non-fi must be a constant. Transition '[durat...time_s]'"duration(t > 20) > time_s"
Component:Stateflow | Category:Coder error
Error while generating code for chart Chart.
ps: I need fixdt(0,16,0.001,0) since I need to generate fixed point code and cannot afford using single or double or any Integer type.
Is there a workaround for this? Thanks in advance

Respuestas (1)

stozaki
stozaki el 25 de En. de 2020
Editada: stozaki el 25 de En. de 2020
't' is a reserved word of the double data type. Therefore, you cannot set attributes such as data type.
I thought that using the after function was one of the workarounds. I have attached a sample model.
  4 comentarios
Renish Ramegowda
Renish Ramegowda el 27 de En. de 2020
Thanks again.
For me, the transition shall happen only after the point, t > 20 is true and then from that point 0.5 sec is completed. Also in between 0.5 sec timer running, if t > 20 condition becomes false, then the time needs to be reset.
for such scenerio, "duration" function was very useful but issue is, it wont accept fixed point data type for time value. For my requirement, all values can only be fixedpoint data type since floting values cannot be accepted in code generation
Question: Why "duration" function dont accept fixed datatype input?
stozaki
stozaki el 30 de En. de 2020
Temporal Logic,
When using Event-Based (tick/CLK): Positive integer
When using Absolute-Time (sec/msec): It is just a positive number, that is, a double type.
So, My model uses Event-Based Temporal Logic. This is a workaround.

Iniciar sesión para comentar.

Categorías

Más información sobre Simulink Functions en Help Center y File Exchange.

Productos


Versión

R2019a

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by