How do I verify BLDC motor fidelity?

2 visualizaciones (últimos 30 días)
William Mercier
William Mercier el 30 de Mzo. de 2020
Respondida: Joel Van Sickel el 1 de Sept. de 2020
I input the parameters of the 3 phase BLDC motor block (https://www.mathworks.com/help/releases/R2019b/physmod/sps/ref/bldc.html) from a specific datasheet, and supplied it with the nominal voltage from the datasheet with 100% duty cycle (using DC voltage source and inverter block) with no load but the simulation's resultant motor speed is less than half of the specified no load speed in the datasheet. Does anyone have an idea about how to fix this problem please?
  1 comentario
Rahul Singh
Rahul Singh el 31 de Mzo. de 2020
Hi William,
Kindly contact MathWorks Technical Support for your query and they can assist you in resolving the issue.
Regards,
Rahul

Iniciar sesión para comentar.

Respuestas (1)

Joel Van Sickel
Joel Van Sickel el 1 de Sept. de 2020
Hello William,
can you share the model in which you apply a duty cycle of 100%? Since a closed loop control algorithm is required to drive a BLDC at max speed, it is possible the closed loop test simulation is incorrect while the parameters are correct. It would also be good to double check wether poles or pole pairs were used in the parameterization as that is an easy place to end up with a factor of 2 error.
Regards,
Joel

Comunidades de usuarios

Más respuestas en  Power Electronics Control

Categorías

Más información sobre Choose and Parameterize Blocks en Help Center y File Exchange.

Community Treasure Hunt

Find the treasures in MATLAB Central and discover how the community can help you!

Start Hunting!

Translated by