Data Acquisition Toolbox doesn't work with Simulink
4 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hello,
I am using the NI 9188 Chassis with different Modules for IO purpose. It works properly with Matlab and the Data Acquisition Toolbox, that means things like
myDAQ = daq.createSession('ni');
myDAQ.addAnalogInputChannel('cDAQ9188-AI' , 'ai0' , 'Voltage');
myDAQ.DurationInSeconds = measurement_time;
myDAQ.Rate = measurement_rate;
myDAQ.startForeground();
are working fine. But when I try the In- and Output Blocks within Simulink, the Blocks only say: Device: none, and I'm not able to configure anything.
I am using Windows XP with NIDAQmx Driver and Matlab 2012a. Things like daq.getVencors oder daq.getDevices are showing up the correct hardware.
What I found out is, that my Hardware is only able to deal with the session base interface. Isn't it supportet with Simulink?
Thanks for any efforts in advance.
0 comentarios
Respuesta aceptada
Pedro Villena
el 29 de Oct. de 2012
Editada: Pedro Villena
el 12 de Nov. de 2012
If you use Real-Time Windows Target Blockset, check if your hardware is in the list of supported hardware.
If you use xPC Target Blockset, check if your hardware is in the list of supported hardware.
Yes, Data Acquisition Toolbox provides blocks that are only available using the Legacy interface and the 32-bit version of MATLAB.
2 comentarios