Simulink is already connected to another real-time model
9 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Hi, I'm using the real-time target and sometimes I get this error:
*Error occurred while executing External Mode MEX-file 'rtwinext':
Simulink is already connected to another real-time model. It is not allowed to connect to multiple real-time models simultaneously*
The only solution that I can apply is to restart the Computer and this is so bad.
I don't know why. Can you help me?
Thanks a lot!
1 comentario
Kaustubha Govind
el 27 de Nov. de 2012
Unless you actually are running multiple Real-Time Windows Target models, you might need to contact MathWorks Tech Support about this. It looks like Simulink does not terminate its connection with the RTWT kernel for some reason, but I don't have enough expertise in this area to make a guess.
Respuesta aceptada
Jan Houska
el 29 de Nov. de 2012
This situation may happen if the real-time code terminates in some unusual way and does not properly disconnect from Simulink. To clean up manually without restarting the computer, please type these two commands:
rtclear
rtunload
If this does not help, a more aggresive way is to reinstall the real-time kernel (which cleans up all previous activities):
rtwintgt -setup
0 comentarios
Más respuestas (1)
Ver también
Categorías
Más información sobre Target Computer Setup en Help Center y File Exchange.
Productos
Community Treasure Hunt
Find the treasures in MATLAB Central and discover how the community can help you!
Start Hunting!