Restart a USB connection
7 visualizaciones (últimos 30 días)
Mostrar comentarios más antiguos
Mathias Westlund
el 17 de En. de 2013
Movida: Walter Roberson
hace alrededor de 22 horas
Hi, I have a hardware intrument with a Matlab GUI that calls a few different USB devices. From time to time a USB connection fails. To resolve this I currently need to restart Matlab, the hardware or unplugg/replug the USB device. Is there a way to restart the USB communication from Matlab wihtout restarting any of the hardware or programs?
Thanks Mathias Westlund
1 comentario
Mickael PIERRE
el 12 de Mzo. de 2021
Hi there,
I have the same issue. Did you find a way around it?
Thank you,
Mickael
Respuesta aceptada
Walter Roberson
el 18 de En. de 2013
Mathworks has said there is no current mechanism to do this.
A small number of people have reported success using instrreset, but that is part of the Instrument Control toolbox.
1 comentario
Más respuestas (1)
Gavin
hace alrededor de 12 horas
See this same issue with a solution here
workaround exists: you can delete the existing serial port connection and then establish a new connection. For example:
myComPort = serial('COM5');
fopen(myComPort);
% Now disconnect the device
delete(myComPort);
clear myComPort;
% Reconnect the device; the following will now be successful:
myComPort = serial('COM5');
fopen(myComPort);
0 comentarios